SPLIT-PROBE SPECTRAL ILLUMINANCE METER
The AMT558 is a portable, split-probe spectral illuminance meter for evaluating lighting performance across a wide range of applications. It measures illuminance, correlated color temperature (CCT), color rendering index (CRI), flicker, UV index, blue-light hazard, and environmental conditions.
As a CCT and CRI meter, it helps users assess the color characteristics of lamps and luminaires. A dedicated plant-lighting mode adds PPFD, spectral PPFD, YPFD, and chlorophyll measurements for horticultural lighting analysis. Its 3.5-inch color touchscreen and spectral curve display make results easy to review in the field, laboratory, or production environment.
| High Range | Illuminance measurement up to 1,000,000 lux |
| Spectral Data | 400 to 700 nm at 10 nm intervals |
| Complete Metrics | Illuminance, CCT, CRI, SDCM, flicker, UV index, blue-light hazard, temperature, humidity |
| Plant Lighting | PPFD, blue/green/red PPFD, YPFD, chlorophyll A and B |
| Split Design | Digital probe for flexible positioning |
| Display | 3.5-inch IPS color touchscreen, storage for up to 1,000 readings |
| Data Export | PC software for batch data export and analysis |
| Units | Selectable lux and foot-candle (fc) |
Lighting laboratories and quality-control facilities; light meters for LED testing and luminaire manufacturing; offices, schools and indoor environments; greenhouses, indoor farms and plant-growth research; street and outdoor lighting projects.
| Parameter | Range / Value | Resolution / Accuracy |
|---|---|---|
| Illuminance wavelength range | 400–700 nm | Spectral interval 10 nm |
| Illuminance | 0–1,000,000 lux | 0.1 lux; ≤ ±(3% of reading + 2 lux) |
| Illuminance units | lux, fc | Selectable |
| CCT | 1,000–100,000 K | ±5% |
| CRI | 0–100 | ±2 |
| UV index | 0.0–15.0 | ±10% |
| Flicker frequency | 10–500 Hz | ±5% |
| Temperature | −40 to 120 °C | ±0.5 °C |
| Relative humidity | 0–100% RH | ±4% RH |
| PPFD | 0–10,000 μmol/m²/s | ≤ ±(5% of reading + 0.5 μmol/m²/s) |
| Blue, green, or red PPFD | 0–5,000 μmol/m²/s each | ≤ ±(10% of reading + 0.5 μmol/m²/s) |
| YPFD | 0–10,000 μmol/m²/s | ≤ ±(5% of reading + 0.5 μmol/m²/s) |
| Chlorophyll A | 0–10,000 μW/cm² | ≤ ±(10% of reading + 0.5 μW/cm²) |
| Chlorophyll B | 0–10,000 μW/cm² | ≤ ±(10% of reading + 0.5 μW/cm²) |
| Response time | < 0.7 s | — |
| Probe aperture | 21 mm diameter | — |
| Display | 480 × 320-pixel IPS color screen | 3.5 inch |
| Data storage | 1,000 readings | — |
| Battery | Rechargeable 3.7 V, 4,000 mAh lithium battery | Power input DC 5 V |
| Operating environment | 0–40 °C;<85% RH | — |
| Dimensions | 141 × 70.4 × 22 mm | Probe: 40 mm diameter × 20 mm thick |
| Weight | Approx. 277 g | — |
Specifications are based on the selected probe configuration and may vary by model. Measurements are traceable to the supplied calibration base.