QUANTUM PAR METER FOR PLANT LIGHT MEASUREMENT
The AMT312 quantum PAR meter measures photosynthetically active radiation (PAR) across the 400–700 nm wavelength range. It is designed for horticultural studies and monitoring plant physiology, where light in this wavelength band is relevant to photosynthesis. The remote sensor connects to the handheld meter by cable, allowing readings to be taken at the location being evaluated.
With a large LCD, measurement hold, and data logging, this PAR meter for plants helps users capture and review light readings during plant-lighting assessments.
| Spectral Range | Measures PAR from 400 to 700 nm |
| Units | Displays readings in μmol/m²/s |
| Display and Hold | Large LCD with measurement hold function |
| Data Logging | Stores readings for later review using the log function |
| Zero Adjustment | Zero-point adjustment is available through the CALI mode |
| Sensor | Handheld meter with a separate wired sensor |
PAR measurement: measures light within the 400–700 nm band.
Hold: freezes the current measurement on the display; press ENTER again to return to live measurement.
Data logging: records measurement readings and provides access to stored history.
Zero adjustment: CALI mode adjusts the zero point. Cover the photosensitive area completely during this procedure.
Factory reset: RCFS mode restores factory settings and erases stored log data.
The AMT312 is suitable for horticultural research and plant physiology monitoring. It can be used to check PAR levels at different positions in a growing area and to document readings during plant-lighting evaluations.
| Parameter | Value |
|---|---|
| Measurement range | 0–3,999 μmol/m²/s |
| Resolution | 0.1 μmol/m²/s from 0–999; 1 μmol/m²/s from 1,000–3,999 |
| Repeatability | ±1 μmol/m²/s |
| Spectral range | 400–700 nm |
| Cut-on wavelength | 400 ±10 nm |
| Cut-off wavelength | 700 ±10 nm |
| Operating temperature | 0 to 50 °C (32 to 122 °F) |
| Storage temperature | −20 to 60 °C (−4 to 140 °F) |
| Operating and storage humidity | 0–95% RH, non-condensing |
| Power supply | 2 × AAA batteries |
| Main unit dimensions | 115 × 60 × 24 mm |
| Sensor unit dimensions | 80 × 45.6 × 26 mm |
| Weight | 115 g, excluding batteries and cable |