AMTAST Lab pH Meter
Keywords: AMT611, lab pH meter, benchtop pH tester, NIST pH calibration, pH/mV meter
Compact 6.0-inch LCD benchtop pH/mV meter with 1–2 point calibration and automatic NIST buffer recognition for routine laboratory testing.
The AMT611 is a dependable benchtop pH meter built for everyday laboratory use. It delivers accurate pH and mV readings with continuous-read stability, ±0.05 pH accuracy, and 0.01 pH resolution across a 0.00–14.00 pH range. Manual temperature compensation (MTC) supports accurate readings from 0.0 to 60.0 °C, and the meter automatically recognises NIST pH buffers (4.01, 7.00, 10.01) to streamline calibration.
The 6.0-inch segment LCD shows pH, mV, and temperature values at a glance, with an adjustable backlight for clear viewing in any lab environment. A BNC (Q9) connector accepts standard pH combination electrodes, and the included short-circuit plug protects the high-impedance input when no electrode is connected. With IP54 protection, power-failure memory, and a configurable EU/UK/US AC-to-DC adapter, the AMT611 is ready for daily work in academic, environmental, and industrial labs.
1. 6.0-Inch Segment LCD — Large display shows pH, mV and temperature with adjustable backlight for easy reading.
2. 1–2 Point Auto/Manual Calibration — Calibrate with NIST pH 4.01, 7.00 and 10.01 buffers, or define your own custom standard.
3. Automatic Buffer Recognition — Auto-identifies pH 4.01, 7.00 and 10.01 standard solutions to streamline routine calibration.
4. Manual Temperature Compensation (MTC) — Adjusts the pH reading for sample temperatures between 0.0 and 60.0 °C.
5. Continuous-Read pH and mV — Stable live readings in pH (0.00–14.00) and mV (-1400 to +1400) modes.
6. Electrode Slope Display — On-screen diagnostics show electrode slope and performance for quick reliability checks.
7. Configurable Auto Shutdown — Programmable from off to 3600 seconds to extend component life.
8. Reset to Factory Defaults — One-touch restore clears user settings and returns the meter to its shipping configuration.
1. Connect the Electrode — Attach the pH combination electrode to the BNC (Q9) socket on the back panel, or fit the short-circuit plug if no electrode is in use.
2. Rinse and Power On — Rinse the electrode with distilled water and blot gently, then switch on the meter using the Power key.
3. Set Temperature (MTC) — Press the Setting/▼ key to enter temperature setting, then adjust to match the temperature of your buffer or sample.
4. Calibrate — Immerse the electrode in pH 7.00 buffer (then pH 4.01 or 10.01 for 2-point calibration), wait for a stable reading, and press Cal → Enter.
5. Measure — Rinse the electrode, immerse it in the sample, set the sample temperature, and record the reading once it stabilises.
6. Switch Units — Use the mV/pH key to toggle between pH and mV display modes during the same session.
| Model | AMT611 |
| pH Range | 0.00 – 14.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.05 pH |
| mV Range (sensor optional) | -1400 – 1400 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.1 % FS |
| Calibration Points | 1 – 2 points, auto or manual |
| Standard Recognition | NIST pH 4.01, 7.00, 10.01 |
| Reading Mode | Continuous |
| Temperature Compensation | Manual (MTC), 0.0 – 60.0 °C |
| pH Electrode Input | BNC (Q9) |
| Display | 6.0-inch segment LCD with backlight |
| Auto Shutdown | Off, 300, 600, 900, 1200, 1500, 1800, 2100, 2400, 2700, 3600 s |
| IP Rating | IP54 |
| Power Supply | AC 110 V/60 Hz or AC 230 V/50 Hz → DC 12 V / 1000 mA |
| Dimensions | 200 × 160 × 63 mm |
| Weight | 600 g (1.32 lb) |
1. Academic and university laboratories — chemistry, biology and life-science course labs
2. Environmental monitoring — acid rain, surface water, industrial wastewater and drinking water analysis
3. Food and beverage testing — finished products, ingredients and beverages
4. Pharmaceutical and medical laboratories — formulation, QC and biological sample prep
5. Geological prospecting and metallurgy — ore, soil and process-solution testing
6. Marine exploration — seawater and aquaculture sample pH measurement
7. Daily chemical and textile QC — cosmetics, detergents, dyes and process water
Optional accessories available for separate purchase — select any combination based on your testing needs:
1. E520BNC pH composite electrode (replacement / spare)
2. mV / ORP sensor (add-on for redox potential measurement, sold separately)
3. NIST pH standard solution sachets — pH 4.01 / 7.00 / 10.01 (3 × 5 sachets per pack)
4. Electrode clip assembly and electrode stem (replacement parts)
5. Configurable AC power adapter — EU / UK / US plug variants