Hygiene & Food Safety Instruments — ATP Fluorescence Detection Series
Keywords: ATP meter, ATP hygiene monitor, ATP test kit, surface cleanliness tester, ATP bioluminescence detector
Detect Surface Cleanliness in Seconds — ATP Bioluminescence, 0 to 9999 RLU.
The ATP-2 is a portable ATP fluorescence detector that measures surface cleanliness and total bacterial levels using bioluminescence technology. By converting the invisible ATP concentration into a visible light output, it reports results in relative light units (RLU) from 0 to 9999, giving you a fast, objective pass/fail reading of hygiene at any control point.
Designed for HACCP monitoring, the ATP-2 works with ATP fluorescence sampling swabs to check dining utensils, desktops, operators' hands, medical work surfaces and scopes. It features a detection limit of ≤1.0 CFU/ml, selectable RLU or coliform screening modes, and storage for more than 3000 results that can be transferred to a PC via USB.
1. ATP Bioluminescence Method — Converts invisible ATP into visible light for quantitative microorganism detection.
2. 0–9999 RLU Range — Reports results in relative light units (1 RLU = 1 fmol ATP) for easy pass/fail comparison against a user-set limit.
3. Fast Detection — Test time from 1 to 60 seconds.
4. High Sensitivity — Precision of 4×10⁻¹⁸ mol ATP and detection limit of ≤1.0 CFU/ml.
5. Dual Screening Modes — Choose RLU or coliform screening, with over 1000 settable limit values.
6. Large Storage & PC Transfer — Stores more than 3000 results and transfers them to a PC via USB.
1. Prepare the Swab — Open the test tube and take out the swab for sampling without touching the swab or test stick.
2. Collect the Sample — Swab the test area (standard area 10 × 10 cm²) to collect the sample.
3. React with Solution — After the sample reacts with the swab solution, insert the swab into the detector.
4. Read Within 2 Minutes — Press the test key and read the RLU result within 2 minutes of the reaction.
5. Compare with Limit — The reading is compared with your preset limit to give a pass or warning result.
| Model | ATP-2 |
| Precision | 4 × 10⁻¹⁸ mol ATP |
| Detection Limit | ≤1.0 CFU/ml |
| Detection Range | 0 – 9999 RLU (Relative Light Unit) |
| Fecal Coliform | ≥1 × 10⁻⁶ CFU |
| Testing Time | 1 – 60 seconds |
| Testing Interference | ±2% or ±2 RLUs |
| Background Value | ≤1 RLU |
| Detection Modes | RLU or coliform screening |
| Settable Limit Values | More than 1000 |
| Storage | More than 3000 results |
| Data Output | USB port, transferable to PC |
| Operating Temperature | 0 – 40°C |
| Relative Humidity | 20% – 85% |
| Dimensions (W×H×D) | 199 × 76 × 37 mm |
| Weight (with battery) | 265 g |
| Power Supply | 2 × 1.5V AA (UM-3) battery |
1. Food industry — HACCP monitoring
2. Public places & indoor environment cleanliness testing
3. Dining utensils, desktops & operator hand hygiene
4. Medical & healthcare operating tables and scopes
5. Total bacterial count screening in production environments
1. ATP fluorescence test swabs (optional)
2. RS-232C data cable with software (optional)