The AMT178 portable water activity meter measures aw from 0.000 to 1.000 with 0.001 aw resolution and ±0.02 aw accuracy. It displays water activity and temperature together and uses a rechargeable battery for convenient testing in the laboratory or near production. A magnetic base holds the sensor head over the sample plate during equilibration and measurement.
1. Measures water activity over a 0.000–1.000 aw range.
2. 0.001 aw display resolution with specified accuracy of ±0.02 aw.
3. Displays water activity and temperature together.
4. Integrated sensor and display with a magnetically secured sample base.
5. Built-in rechargeable battery and USB charging.
6. USB PC connection for compatible data software.
7. User adjustments for water activity and temperature calibration.
8. Portable 310 g instrument for on-site sample checks.
| Parameter | Specification |
|---|---|
| Model | AMT178 |
| Measurement range | 0.000–1.000 aw |
| Resolution | 0.001 aw |
| Accuracy | ±0.02 aw |
| Sensor | non-conductive humidity sensor |
| Standard measurement time | approximately 5 minutes after equilibration; wait for a stable reading |
| Sample equilibration time | approximately 5–15 minutes |
| Displayed parameters | water activity and temperature |
| Power supply | built-in rechargeable battery |
| PC connection and charging | USB |
| Operating temperature | 0–50°C |
| Operating humidity | <95% RH |
| Dimensions | 138 × 73 × 30 mm |
| Weight | 310 g |
1. Water activity checks of food and grain samples during quality control.
2. Comparing batches of dried foods, baked goods, powders, fruits, and vegetables.
3. Supporting packaging, storage, and product development evaluations with aw measurements.
4. Laboratory and production-area checks where a portable meter is useful.
Water activity describes the availability of water in a sample, rather than its total moisture percentage. Select the AMT178 when aw is the required parameter; a moisture-content analyzer measures a different property. Its 0.001 aw resolution is the displayed increment, while ±0.02 aw is the stated measurement accuracy.
Allow approximately 5–15 minutes for the sample and sensor to equilibrate before the measurement stage. The standard measurement stage takes about 5 minutes, so this is not a five-minute total workflow. High or low aw samples may require longer measurement times until the reading stabilizes.
Fill the sample plate to at least two-thirds of its capacity. Hold the base firmly while positioning or removing the sensor head to prevent spills. Allow the covered sample to equilibrate, start measurement, and wait for a stable reading. Clean the sample plate before the next test. The instrument is not waterproof; keep liquids out of the probe and housing.
Before calibration, allow the instrument, reference solution, and room to reach the same temperature. The manual specifies saturated NaCl solution at 0.753 aw at 25°C (77°F). Use the appropriate temperature-dependent reference value, then adjust the aw offset if required. Temperature adjustment uses a reference thermometer. Charge when the battery indicator is low and do not exceed eight hours of continuous charging.